Material Testing Machines | 0.001 mm Precision | Br&Qmesys
CN
Calibration & Metrology Services

Every measurement,
traceable and repeatable

Factory-trained engineers calibrate force, displacement, temperature and speed on site. Working standards trace to national metrology benchmarks, and every report is fully traceable — trustworthy data starts with calibration.

Factory calibration for force, displacement, temperature & speed — traceable to national metrology standards.

±0.5%
Force accuracy F.S.
0.5–1 day
On-site calibration
Full scale
Indication check

Force Calibration

Displacement Calibration

Temperature Calibration

Speed Calibration

24h
Response time
48h
On-site support
Full lifecycle
Technical support
On-Site In-House Traceable Reports Quality Audits

Why Regular Calibration

Trustworthy data starts with calibration

Every measuring instrument drifts over time. Mechanical wear, temperature swings, sensor ageing and environmental vibration quietly pull your test data away from the true value — and you may never notice it.

01

Data Integrity

An uncalibrated instrument can develop systematic bias — R&D experiments become impossible to reproduce, production QC misjudges yield, and customer audits reject the data.

02

Compliance & Audits

ISO 9001, IATF 16949 and customer system audits all require traceable measuring equipment. A regular calibration report is an essential audit document.

03

Longer Equipment Life

Calibration also checks mechanical alignment, sensor condition and control logic — catching wear early and avoiding sudden breakdowns and costly repairs.

Metrology Traceability Chain

Every measurement, traceable to the SI

Your Instrument
Laboratory test equipment
Br&Qmesys Standards
Portable working standards, carried on site
National Primary Standards
National Institute of Metrology (NIM), China
SI
International System of Units (SI)
The globally unified basis of measurement

Calibration Scope

Four measurement dimensions, one complete coverage

From force to temperature, from displacement to speed — every instrument in the Br&Qmesys range can be calibrated.

01

Force Calibration

Full-range indication error and repeatability checks for universal testing machines, hot presses and impact testers.

ISO 7500-1 · ASTM E4 | 0.1 kN – 300 kN

02

Displacement & Strain

Crosshead travel, platen stroke and extensometer channel verification.

JJF 1345 | Resolution & linearity

03

Temperature Calibration

Platen temperature uniformity and chamber zones — ambient to 750 °C.

JJF 1304 | PID temperature control verification

04

Speed & Geometry

Crosshead speed, impact velocity, platen parallelism and alignment.

Factory specifications | Fixture coaxiality

Delivery Options

On-site calibration, or deep in-house calibration

Choose based on your equipment's condition and downtime window.

Recommended

On-site calibration

Our engineers bring the working standards to your lab — no disassembly or shipping required. Ideal for production lines, large instruments and systems that can't be moved.

✓ In-situ calibration, nothing to move

✓ Completed in 0.5–1 working day

✓ Weekends or planned shutdowns available

✓ Verified on site after calibration

Alternative

In-house calibration

Your instrument returns to our Shenzhen headquarters for full-scope calibration and deep inspection in a temperature-controlled metrology lab. Best for compact instruments or systems needing major service.

✓ Temperature-controlled metrology lab

✓ Full deep inspection and adjustment

✓ Ageing parts replaced in the same visit

✓ Around 5–7 working days

The OEM Advantage

What third parties can't do — only the OEM can

Third-party labs don't understand Br&Qmesys control logic or sensor calibration parameters. Our engineers hold the as-shipped baseline for every machine.

01

Factory Baseline Data

Every instrument stores its full-range calibration data at the factory. We compare against these as-shipped values to detect wear and sensor drift trends.

02

Proprietary Control Logic

Only factory engineers can verify PID closed-loop consistency on the QM900A-U and QM910 HCS systems.

03

Calibration & Repair in One Visit

If readings fall out of tolerance, we adjust or replace parts on the spot — no second visit, less downtime.

How It Works

Calibration in Five Steps

STEP 01

Book

Share your model number and preferred time window

STEP 02

Quote

Scope and schedule confirmed within 1 business day

STEP 03

On-site calibration

Engineers arrive with traceable standards

STEP 04

Report Delivery

Data and next-due recommendations delivered

STEP 05

Due-Date Reminder

We track due dates and remind you in advance

Calibration Report

One report,
straight into your quality file

Within 3 business days of every calibration, you'll receive a PDF report recording indication error, correction and uncertainty at each test point — ready to support ISO 9001 / IATF 16949 system audits.

✓ Indication error and correction at each load point

✓ Working standard IDs and traceability certificate numbers

✓ Environmental conditions (temperature / humidity)

✓ Engineer signature and recommended next calibration date

Sample Report
CALIBRATION REPORT
CR-2026-0847
Calibrated
Instrument
QM900A-U
Range
0.1–100 kN
NominalIndicatedError
10 kN10.01 kN+0.1%
50 kN49.98 kN−0.04%
100 kN99.95 kN−0.05%
Next due
Oct 2027
✓

FAQ

Frequently Asked Questions

Straight answers on calibration certificates, turnaround and response — before you even ask.

Is your calibration report a CNAS-accredited certificate? ×
We issue OEM calibration reports recording indication error and adjustments at each point. Our working standards are regularly traced to national metrology benchmarks. If your system audit requires a CNAS-accredited statutory certificate, we can arrange on-site calibration with a partner third-party lab, whose report is issued by that lab.
How long does calibration take? Will it affect production? +
On-site calibration of a single instrument takes about 0.5–1 working day. We can schedule weekends or planned shutdowns, and recommend production-line customers book two weeks ahead.
What happens if an out-of-tolerance reading is found? +
Our engineer assesses on site whether the instrument can be adjusted. If parameter correction resolves it, we recalibrate and record the result immediately. If sensors or mechanical parts need replacing, we quote first and return for a second visit — free of charge for annual-contract customers.
How is calibration arranged for overseas equipment? +
Customers outside China are served by locally authorized service engineers who calibrate on site, with the OEM report issued by headquarters. For cross-border relocation projects, a factory engineer — or a local engineer with three years of factory training — can accompany the move.
Can you calibrate equipment from other brands? +
We primarily serve Br&Qmesys instruments. For equivalent third-party equipment — universal testing machines, hot presses and impact testers — we can provide calibration after an on-site assessment, but we don't issue OEM reports for it.

A calibration plan built for your equipment

Tell us your instrument model and location. We'll send a quote and available time windows within one business day.

How can I help you?
Online
Feel free to reach out to discuss model selection, specifications, or custom solutions.
Free selection consultation · Direct access to professional engineers · No sales pressure
Have questions? Chat with us